Solar Panels and Home Battery Backup: What Is Islanding?
Islanding is when your home, or just its backed-up circuits, temporarily runs on a local electricity supply while safely separated from the public grid. Here’s what happens from the moment the mains goes off to the point it comes back.

Illustration of a home keeping some lights on with backup power during a power cut.
What is islanding?
Think of the backed-up circuits as a small electrical island. During normal operation they can use mains electricity. In island mode, they use power from a compatible battery and inverter, plus solar when the system can use it. A standard grid-connected solar inverter usually shuts down when it loses mains power.
Separating the backed-up circuits from the public grid prevents electricity from being fed back onto lines that may be unsafe to energise. The installer must verify that electrical protection works in both modes. See the IET’s guidance on safe island-mode operation.
What happens when the power goes off and comes back?
In an automatic setup, the system detects the outage and isolates the backed-up circuits from the grid. The battery inverter establishes a local supply so those circuits can run again. There can be a brief interruption while it switches over. Once the system confirms the mains supply is stable, it reconnects to the grid.
For the equipment that manages this switch and what to check in a quote, read our backup gateway guide.
Will the solar panels still charge the battery?
With compatible equipment, the panels can supply the backed-up circuits in daylight and use any surplus to recharge the battery. If the battery is full and the house is using very little electricity, the system may reduce solar output. When there’s no solar generation, the battery supplies the circuits until it reaches its minimum charge. Whether the system can restart from solar the next morning depends on its design.
How long can the battery keep going?
Runtime depends on how much usable energy is left in the battery and how quickly the backed-up circuits use it. For example, 5 kWh of available energy could run a steady 500 W load for about 10 hours before allowing for losses, assuming the solar panels add no more energy. Using more power shortens the runtime.
How this fits into our household trial
We’re testing what happens in our own solar-and-battery setup as well as tracking electricity costs. Read our solar and home battery trial for the system specification and loan figures.
Where the emergency generator fits
We plan to add a generator for longer power cuts, when the battery is running low and the solar panels cannot keep up. We’re designing it for two possible uses. It could recharge the home battery so the battery can carry on supplying the backed-up circuits. Or the system could switch over so the generator powers those essential circuits directly.
The aim is to keep a few essentials running, such as refrigeration and some lighting. We’ll agree the exact circuits and power limits with the installer. We’re also looking at whether the generator could start and stop automatically, but the controls and changeover design are still being worked out.
The installer will need to verify that the generator, inverter and protection work together and that the system cannot feed electricity back onto the public network. We’re considering an outdoor location and will also ask the installer whether a fixed generator specifically designed and approved by its manufacturer for indoor installation could be safely housed in the garage. That would require a professionally designed exhaust and ventilation system. A portable or outdoor-only generator must stay outdoors, away from doors, windows and vents. Running an exhaust pipe outside does not make it safe to use one in a garage because carbon monoxide can still build up or enter the house. We also plan to fit an audible carbon monoxide (CO) alarm to warn people in the home if it detects carbon monoxide. It’s an additional safeguard. Safe siting, exhaust and ventilation are still essential. Read the Health and Safety Executive for Northern Ireland’s generator safety advice.